An improved time domain arc furnace model for harmonic analysis
Author
Alonso, M. Anxo Prieto ; Donsión, Manuel Pérez
Author_Institution
Dept. of Electr. Eng., Vigo Univ., Spain
Volume
19
Issue
1
fYear
2004
Firstpage
367
Lastpage
373
Abstract
In this paper, an arc model is presented to carry out harmonic analysis of an AC three-phase arc furnace with a single-phase circuit. This model is based on the V-I characteristic of the arc and takes into account the effect of the arcs unbalance over the zero sequence harmonics. The model is implanted in EMTDC and tuned with field data. Simulations are performed in continuous work using Monte Carlo method to obtain arc length. Simulations results obtained with this model are compared for the main harmonics with actual data and simulation data obtained with other models. The comparison is carried out with the probability density functions of the harmonics.
Keywords
Monte Carlo methods; arc furnaces; harmonic analysis; harmonic distortion; power system harmonics; probability; time-domain analysis; AC three-phase arc furnace; Monte Carlo method; V-I characteristic; electric arc furnace model; harmonic analysis; power system harmonics; probability density function; time domain model; unbalanced operation; zero sequence harmonics; Circuit simulation; Furnaces; Harmonic analysis; Milling machines; Power harmonic filters; Power system harmonics; Steel; Time domain analysis; Transformers; Voltage;