DocumentCode
85346
Title
Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET
Author
Yanguang Lin ; Haldar, Justin P. ; Quanzheng Li ; Conti, Peter S. ; Leahy, Richard M.
Author_Institution
Signal & Image Process. Inst., Univ. of Southern California, Los Angeles, CA, USA
Volume
33
Issue
1
fYear
2014
fDate
Jan. 2014
Firstpage
173
Lastpage
185
Abstract
The estimation and analysis of kinetic parameters in dynamic positron emission tomography (PET) is frequently confounded by tissue heterogeneity and partial volume effects. We propose a new constrained model of dynamic PET to address these limitations. The proposed formulation incorporates an explicit mixture model in which each image voxel is represented as a mixture of different pure tissue types with distinct temporal dynamics. We use Cramér-Rao lower bounds to demonstrate that the use of prior information is important to stabilize parameter estimation with this model. As a result, we propose a constrained formulation of the estimation problem that we solve using a two-stage algorithm. In the first stage, a sparse signal processing method is applied to estimate the rate parameters for the different tissue compartments from the noisy PET time series. In the second stage, tissue fractions and the linear parameters of different time activity curves are estimated using a combination of spatial-regularity and fractional mixture constraints. A block coordinate descent algorithm is combined with a manifold search to robustly estimate these parameters. The method is evaluated with both simulated and experimental dynamic PET data.
Keywords
biological tissues; compressed sensing; constraint handling; image representation; medical image processing; parameter estimation; physiological models; positron emission tomography; time series; Cramer-Rao lower bounds; block coordinate descent algorithm; constrained formulation; constrained model; distinct temporal dynamics; dynamic PET data; dynamic positron emission tomography; explicit mixture model; fractional mixture constraint; image voxel representation; kinetic parameter estimation; linear parameters; noisy PET time series; partial volume effect; prior information; pure tissue types; rate parameters; sparse signal processing method; sparsity constrained mixture modeling; spatial-regularity constraint; time activity curves; tissue compartments; tissue fraction; tissue heterogeneity; two-stage algorithm; Blood; Computational modeling; Estimation; Kinetic theory; Parameter estimation; Positron emission tomography; Stability analysis; Compartment model; dynamic positron emission tomography (PET); kinetic parameter estimation; mixture modeling; sparsity;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2013.2283229
Filename
6657752
Link To Document