• DocumentCode
    86187
  • Title

    X-ray CT Metal Artifact Reduction Using Wavelet Domain L_{0} Sparse Regularization

  • Author

    Mehranian, Abolfazl ; Ay, Mohammad Reza ; Rahmim, Arman ; Zaidi, Habib

  • Author_Institution
    Div. of Nucl. Med. & Mol. Imaging, Geneva Univ. Hosp., Geneva, Switzerland
  • Volume
    32
  • Issue
    9
  • fYear
    2013
  • fDate
    Sept. 2013
  • Firstpage
    1707
  • Lastpage
    1722
  • Abstract
    X-ray computed tomography (CT) imaging of patients with metallic implants usually suffers from streaking metal artifacts. In this paper, we propose a new projection completion metal artifact reduction (MAR) algorithm by formulating the completion of missing projections as a regularized inverse problem in the wavelet domain. The Douglas-Rachford splitting (DRS) algorithm was used to iteratively solve the problem. Two types of prior information were exploited in the algorithm: 1) the sparsity of the wavelet coefficients of CT sinograms in a dictionary of translation-invariant wavelets and 2) the detail wavelet coefficients of a prior sinogram obtained from the forward projection of a segmented CT image. A pseudo- L0 synthesis prior was utilized to exploit and promote the sparsity of wavelet coefficients. The proposed L0-DRS MAR algorithm was compared with standard linear interpolation and the normalized metal artifact reduction (NMAR) approach proposed by Meyer using both simulated and clinical studies including hip prostheses, dental fillings, spine fixation and electroencephalogram electrodes in brain imaging. The qualitative and quantitative evaluations showed that our algorithm substantially suppresses streaking artifacts and can outperform both linear interpolation and NMAR algorithms.
  • Keywords
    brain; computerised tomography; dentistry; electroencephalography; image segmentation; medical image processing; prosthetics; wavelet transforms; CT sinograms; DRS algorithm; Douglas-Rachford splitting algorithm; Meyer model; NMAR algorithms; X-ray CT metal artifact reduction; X-ray computed tomography imaging; brain imaging; dental fillings; electroencephalogram electrodes; hip prostheses; metal artifact reduction algorithm; metallic implants; normalized metal artifact reduction approach; segmented CT image; spine fixation; standard linear interpolation; translation-invariant wavelets; wavelet domain L0 sparse regularization; Computed tomography; Dictionaries; Image reconstruction; Implants; Metals; Wavelet domain; Wavelet transforms; $L_{0}$ sparse regularization; Metal artifact reduction (MAR); X-ray computed tomography (CT); streaking artifacts; wavelets; Algorithms; Artifacts; Computer Simulation; Electroencephalography; Head; Hip; Humans; Image Processing, Computer-Assisted; Models, Biological; Phantoms, Imaging; Spine; Tomography, X-Ray Computed; Wavelet Analysis;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2013.2265136
  • Filename
    6522894