• DocumentCode
    86912
  • Title

    Analysis in the Context of Space Radiation Hardness Assurance of Low Dose Rate Results Obtained With the MIL and ESCC Test Methods

  • Author

    Marec, R. ; Carlotti, J.F. ; Marin, Mario ; Calvel, P. ; Barillot, C. ; Mancini, R. ; Sarno, M. ; Melotte, M. ; Cueto, J.

  • Author_Institution
    Thales Alenia Space, Toulouse, France
  • Volume
    61
  • Issue
    5
  • fYear
    2014
  • fDate
    Oct. 2014
  • Firstpage
    2735
  • Lastpage
    2740
  • Abstract
    We present results on the effects of ELDRS at dose rates in the range of the 10-100 mrad(Si)/s corresponding to the low dose rate window of the Test Method ESCC Basic Specification No. 22900 in comparison with 10 mrad(Si)/s as required by the MIL-STD-883J, Test Method 1019.9 on different space qualified bipolar part types. The difference on the results are analyzed in the context of the standard Thales Alenia Space Radiation Hardness Assurance Program as applied to a space telecom project.
  • Keywords
    dosimetry; radiation hardening (electronics); ELDRS; ESCC test method; MIL test method; Thales Alenia Space Radiation Hardness Assurance Program; low dose rate results; space radiation hardness assurance; space telecom project; Context; Degradation; Military standards; Radiation effects; Sensitivity; Testing; Enhanced low dose rate sensitivity (ELDRS); radiation hardness assurance (RHA); test method;