DocumentCode :
870091
Title :
A Novel Scatter Detector for High-Resolution SPECT Imaging With Compton Telescopes
Author :
Castoldi, A. ; Galimberti, A. ; Guazzoni, C. ; Struder, L. ; Walenta, A.H.
Author_Institution :
Ist. di Ingegneria Nucl., Politecnico di Milano
Volume :
53
Issue :
6
fYear :
2006
Firstpage :
3912
Lastpage :
3917
Abstract :
We propose a novel Silicon Drift Detector (SDD) that can fulfill the demanding requirements of the ideal scatter detector for a high-resolution Compton Camera for medical imaging. This kind of detector demonstrates excellent performance in terms of energy and position resolution, maximum readout rate and the more relevant results are reported. The SDD proposed here is based on a multilinear architecture [controlled drift detector (CDD)] in which the backside has been segmented and instrumented to pick up the signal induced by the electron-hole (e-h) pairs generated by the interaction thus providing a fast coincidence signal between the recoil electron signal and the scattered gamma-ray signal. Several measurements have been carried out to study the shape of the induced signals and the achievable time resolution. Experimental tests with annihilation photons of a 22 Na source in a time coincidence setup showed best time resolution of 6 ns FWHM. These results confirm that SDD technology with fast pickup on the back electrodes and optimized design has the potential to develop a Compton telescope with Doppler limited performance for medical imaging
Keywords :
Compton effect; biomedical imaging; coincidence techniques; readout electronics; silicon radiation detectors; single photon emission computed tomography; 22Na source; CDD; Compton imaging; Compton telescopes; Doppler limited performance; SDD technology; annihilation photons; back electrodes; coincidence signal; controlled drift detector; electron-hole pairs; energy resolution; high-resolution Compton Camera; high-resolution SPECT imaging; maximum readout rate; medical imaging; multilinear architecture; novel Silicon Drift Detector; novel scatter detector; position resolution; recoil electron signal; scattered gamma-ray signal; time coincidence setup; Biomedical imaging; Cameras; Detectors; Electromagnetic scattering; High-resolution imaging; Particle scattering; Shape measurement; Signal resolution; Silicon; Telescopes; Compton imaging; SPECT; Silicon Drift Detector (SDD); scatter detector;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2006.884095
Filename :
4033294
Link To Document :