Title :
A method for detecting the transition from corona from water droplets to dry-band arcing on silicone rubber insulators
Author :
Lopes, Ivan J S ; Jayaram, Shesha H. ; Cherney, Edward A.
Author_Institution :
Dept. of Electr. & Comput. Eng., Waterloo Univ., Ont., Canada
fDate :
12/1/2002 12:00:00 AM
Abstract :
The paper presents an investigation on the use of partial discharge (PD) as a means to study the development of leakage current (LC) on silicone rubber insulators in a salt-fog chamber. Simultaneous measurements of LC and PD on dead-end type silicone rubber insulators exposed to different combinations of electrical stress and salt-fog salinity are performed. The results show that for an electrical stress of 33 V/mm applied to the insulator, the average LC experiences gradual changes and reaches a critical level (around 1 mA) where dry-band arcing is observed after 20 minutes at 2300 μS/cm, and after 25 minutes at 1800 μS/cm. The corresponding PD levels reach hundreds of pC after 15 minutes at 2300 μS/cm, and after 20 minutes at 1800 μS/cm. For a salinity corresponding to 1800 μS/cm and stress of 26 V/mm, the LC changes much more gradually and reaches the critical level only after approximately 60 minutes. The corresponding PD reaches hundreds of pC after 30 minutes and more than 1500 pC after 60 minutes. Pattern recognition techniques have been applied to investigate the transition from corona to dry-band arcing. The features extracted from the maximum and mean apparent charge trends are found to be useful to cluster and classify the two phenomena. Simultaneous visual observations of the discharges on the insulator surface support the results. The investigation, therefore, shows that PD is a sensitive method for detecting the transition from corona from water droplets to dry-band arcing and an alternative method for studying the early aging stage of silicone rubber insulators.
Keywords :
arcs (electric); corona; drops; insulator testing; leakage currents; partial discharges; pattern recognition; silicone rubber insulators; 15 to 25 min; corona; dead-end type silicone rubber insulators; dry-band arcing; electrical stress; leakage current; partial discharge; pattern recognition techniques; salt-fog chamber; salt-fog salinity; silicone rubber insulators; water droplets; Corona; Dielectrics and electrical insulation; Electric variables measurement; Leakage current; Partial discharge measurement; Partial discharges; Pattern recognition; Performance evaluation; Rubber; Stress measurement;
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
DOI :
10.1109/TDEI.2002.1115491