DocumentCode
871032
Title
Comparison between measured and theoretical nonlinear behaviour of 4-cavity klystrons
Author
Eaton, J.L. ; Whythe, D.J.
Author_Institution
BBC, Research Department, Tadworth, UK
Volume
3
Issue
2
fYear
1967
fDate
2/1/1967 12:00:00 AM
Firstpage
55
Lastpage
57
Abstract
Measured distortions of television signals and levels of harmonics and intermodulation products occurring in a 4-cavity klystron are shown to be in reasonable agreement with values calculated using the 2-cavity ballistic theory. It is concluded that the measured nonlinearity of the klystron is largely fundamental to its mode of operation.
Keywords
klystrons;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19670043
Filename
4207105