• DocumentCode
    872058
  • Title

    In-Vitro and In-Vivo Trans-Scalp Evaluation of an Intracranial Pressure Implant at 2.4 GHz

  • Author

    Kawoos, Usmah ; Tofighi, Mohammad-Reza ; Warty, Ruchi ; Kralick, Francis A. ; Rosen, Arye

  • Author_Institution
    Sch. of Biomed. Eng., Drexel Univ., Philadelphia, PA
  • Volume
    56
  • Issue
    10
  • fYear
    2008
  • Firstpage
    2356
  • Lastpage
    2365
  • Abstract
    Elevation of intracranial pressure is one of the most important issues in neurosurgery and neurology in clinical practice. The prevalent techniques for measuring intracranial pressure require equipments that are wired, restricted to a hospital environment, and cause patient discomfort. A novel method for measuring the intracranial pressure is described. A wireless completely implantable device, operating at an industrial-scientific-medical band of 2.4 GHz, has been developed and tested. In-vitro and in-vivo evaluations are described to demonstrate the feasibility of microwave pressure monitoring through scalp, device integrity over a long period of time, and repeatability of pressure measurements. A distinction between an epidural and sub-dural pressure monitoring techniques is also described. Histo-pathological results obtained upon a long-term device implantation favor the utilization of the sub-dural pressure monitoring method. On the other hand, in-vivo studies illustrate a maximum pressure reading error of 0.8 mm middot Hg obtained for a sub-dural device with a capacitive microelectromechanical system sensor compared to 2 mm middot Hg obtained for an epidural device with a piezoresistive sensor.
  • Keywords
    biomedical telemetry; brain; capacitive sensors; microsensors; microwave devices; neurophysiology; patient monitoring; piezoresistive devices; pressure measurement; capacitive microelectromechanical system sensor; epidural device; frequency 2.4 GHz; intracranial pressure implant; intracranial pressure measurement; microwave pressure monitoring; neurology; neurosurgery; piezoresistive sensor; pressure 0.8 mm Hg; pressure 2 mm Hg; sub-dural device; trans-scalp evaluation; wireless completely implantable device; 2.4-GHz industrial–scientific–medical (ISM) band; Intracranial pressure; microelectromechanical systems (MEMS) capacitive sensors; wireless implants;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.2008.2004253
  • Filename
    4631475