DocumentCode
872949
Title
Cross Talk in Multielectrode Particle Detectors
Author
Richer, J.P. ; Chase, R.L.
Author_Institution
Laboratoire de l´´Accélérateur Linéaire, Orsay
Volume
31
Issue
1
fYear
1984
Firstpage
258
Lastpage
263
Abstract
In highly segmented particle detectors, the crosstalk coupling capacitance between segments may vary from several per cent to as much as 30 % of the total electrode capacitance. Techniques for reducing associated errors by using flat-topped filter weighting functions and low input inpedance preamplifiers will be presented. The damping of resonances due to lead inductance and transformer leakage inductance, which strongly affect the crosstalk signals, will be discussed. Practical circuits using sample-and-hold techniques will be presented.
Keywords
Capacitance; Circuits; Crosstalk; Damping; Electrodes; Filters; Inductance; Preamplifiers; Radiation detectors; Resonance;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1984.4333258
Filename
4333258