• DocumentCode
    874819
  • Title

    Shunt Impedance of Klystron Cavities

  • Author

    Ginzton, E.L. ; Nalos, E.J.

  • Volume
    3
  • Issue
    5
  • fYear
    1955
  • fDate
    10/1/1955 12:00:00 AM
  • Firstpage
    4
  • Lastpage
    7
  • Abstract
    Values of R/Qf or re-entrant resonators are given for configurations for which neither the coaxial-field nor the radial-field approximations are valid. The values are calculated by net point methods, and agree well with experimental values obtained by perturbation methods. Some errors arising from the finite dimensions of perturbing plungers are also discussed.
  • Keywords
    Accuracy; Coaxial components; Frequency estimation; Gyroscopes; Impedance measurement; Klystrons; Maxwell equations; Perturbation methods; Q measurement; Resonant frequency;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0097-2002
  • Type

    jour

  • DOI
    10.1109/TMTT.1955.1124968
  • Filename
    1124968