• DocumentCode
    876263
  • Title

    Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions

  • Author

    Santos-Martin, David ; Rodriguez-Amenedo, Jose Luis ; Arnalte, Santiago

  • Author_Institution
    Dept. of Electr. Eng., Univ. Carlos III, Leganes
  • Volume
    23
  • Issue
    5
  • fYear
    2008
  • Firstpage
    2328
  • Lastpage
    2336
  • Abstract
    This paper analyzes the effects of unbalanced voltage on doubly fed induction generators. It also presents a novel control strategy based on direct power control (DPC+) applied to this type of generators, predominant in wind energy applications, that enables them to work under perturbed conditions and achieve optimum results. Although the technique can be implemented to control both rotor converters and grid converters, we will hereby exemplify the former which regulates stator active and reactive power. The results obtained with DPC+ are then compared through experimental tests to indicate that the technique is suitable and achieves good dynamic responses while controlling current distortion, power or torque oscillations. The validation of results has been performed through experimental tests on a 20-kW generator.
  • Keywords
    asynchronous generators; electric current control; machine control; power control; power convertors; power grids; torque control; current distortion control; direct power control; doubly fed induction generator; grid converters control; power 20 kW; reactive power; rotor converters control; stator power; torque oscillations control; unbalanced grid voltage conditions; wind energy applications; Direct power control (DPC+); doubly fed induction generator (DFIG); unbalanced voltage; voltage dip;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2008.2001907
  • Filename
    4636745