DocumentCode
879487
Title
Beam Vacuum Chamber Effects It the CERN Large Hadron Collider
Author
Vos, L.
Author_Institution
CERN, Geneva, Switzerland
Volume
32
Issue
5
fYear
1985
Firstpage
2347
Lastpage
2349
Abstract
The vacuum chamber of the Large Hadron Collider (LHC) which could be installed above LEP in the LEP tunnel, would be maintained at liquid helium temperature. The power losses from the beam induced wall currents should be minimized in order to reduce the heat load on the cryogenic system. it is shown that stainless steel leads to unacceptably high heating rates due to its high resistivity. On the contrary, the study of the beam chamber coupling impedance shows that with a copper plated vacuum chamber the losses for the LHC beam could be kept below 14 mWm-1, which is much smaller than the unavoidable synchrotron radiation losses. The data on resistivity and impedance are further exploited to evaluate beam stability. The conclusions are that the nominal beam is stable for the resistive wall effect and has comfortable safety margins for the transverse mode coupling, the longitudinal microwave and coupled bunch instabilities.
Keywords
Colliding beam devices; Conductivity; Cryogenics; Helium; Impedance; Large Hadron Collider; Optical coupling; Steel; Structural beams; Temperature;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4333908
Filename
4333908
Link To Document