DocumentCode
880451
Title
RF System for a 1 GeV Pulse Stretcher Ring
Author
Sargent, C.P. ; Flanz, J.B.
Author_Institution
MIT-Bates Accelerator Center Middleton, Massachusetts 01949
Volume
32
Issue
5
fYear
1985
Firstpage
2614
Lastpage
2616
Abstract
A design study has been completed for the RF system of a pulse stretcher ring to be operated in conjunction with the Bates Linear Accelerator (BLA). The 390m circumference ring is to operate from 300 MeV to 1 GeV, with 80 mA injected current and 1 msec extraction time. The stretcher ring is for nuclear physics research and has radiation damping time and quantum lifetime long compared to the extraction time. The special requirements of the RF system have been considered. Dynamic behavior at the fundamental frequency has been investigated by computer simulation. Higher-order mode impedance limitation has been specified by an investigation of transverse multi-bunch multi-turn instabilities.
Keywords
Apertures; Impedance; Linear accelerators; Nuclear physics; Radio frequency; Synchrotrons; System performance; Tuning; Voltage;