DocumentCode
882385
Title
NSLS RF System Improvements
Author
Keane, J. ; Thomas, M. ; McKenzie-Wilson, R. ; Alsace, R.D. ; Ackerman, H. ; Biscardi, R. ; Langenbach, H. ; Ramirez, G.
Author_Institution
Brookhaven National Laboratory Upton, NY 11973
Volume
32
Issue
5
fYear
1985
Firstpage
2784
Lastpage
2785
Abstract
It is required that the NSLS X-ray accelerator reach an energy of 2.5 GeV. An additional accelerating cavity and power amplifier system were installed to meet this goal. A new control system was designed to include phase and amplitude servos as well as computer interfacing. Commissioning and operating experience will be reported.
Keywords
Acceleration; Computer errors; Control systems; Power amplifiers; Radio frequency; Radiofrequency amplifiers; Resonance; Servomechanisms; Tuners; Voltage control;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4334180
Filename
4334180
Link To Document