DocumentCode
897976
Title
Synchronous reluctance motor operating point dependent parameter determination
Author
Wung, Peter Y P ; Puttgen, Hans B.
Author_Institution
Sch. of Electr. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
Volume
28
Issue
2
fYear
1992
Firstpage
358
Lastpage
363
Abstract
An operating point dependent approach toward the modeling of the synchronous reluctance motor is considered. The Fock and Hart testing method is used to obtain the motor parameter values x d , x q, and r for different values of input voltage magnitude and frequency. From the accumulated points, a 3-D surface for each parameter is generated and a function is formulated to describe the surface. As a result of this modeling technique, an input variant nonlinear model of the motor is obtained such that a nonlinear control technique can be applied for a more precise control strategy
Keywords
machine testing; parameter estimation; reluctance motors; 3-D surface; Fock and Hart testing method; equivalent circuits; input frequency; input variant nonlinear model; input voltage magnitude; nonlinear control technique; operating point dependent approach; parameter determination; synchronous reluctance motor; Equations; Equivalent circuits; Frequency; Industry Applications Society; Reluctance motors; Robust control; Rotors; Synchronous machines; Synchronous motors; Voltage;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.126742
Filename
126742