DocumentCode :
901222
Title :
A Radiation-Hardened Accelerometer Preamplifier for 2 Ã\x97 108 Rads(Si) Total Dose
Author :
Binkley, David M.
Author_Institution :
Technology for Energy Corporation One Energy Center, Pellissippi Parkway Knoxville, Tennessee 37922
Volume :
29
Issue :
6
fYear :
1982
Firstpage :
1499
Lastpage :
1507
Abstract :
The application of a radiation-hardened preamplifier used in a relief-valve monitoring system for nuclear power plants is described. Design objectives and design details are given for the preamplifier, with particular attention directed toward radiation tolerance against the postulated gamma accident dose of 2 × 108 rads(air) for nuclear power plant containment. Data presented from a semiconductor device radiation test, as well as radiation testing on the preamplifier, support its capability to survive this accident dose. The preamplifier is built from commercial discrete JFET and bipolar transistor components.
Keywords :
Accelerometers; Accidents; Circuits; Coaxial cables; Impedance; Power generation; Preamplifiers; Semiconductor device testing; Valves; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1982.4336394
Filename :
4336394
Link To Document :
بازگشت