Title :
A graphical approach to hydrogenerator governor tuning
Author_Institution :
Dept. of Gen. Eng., Illinois Univ., Urbana, IL, USA
fDate :
9/1/1990 12:00:00 AM
Abstract :
A graphical approach to hydrogenerator governor tuning is described. A graph which is developed can be used to predict optimum proportional and integral gains based on four parameters: the time constants of the water column and of the rotor inertia, and the self-regulation constants of the turbine and of the loading grid. The pole cancellation method of design is used, and the results are posed in an easy-to-use format that does not require the solution of systems of equations. Information on stability limits and comparisons with other work are included
Keywords :
hydroelectric generators; self-adjusting systems; stability; three-term control; PID control; graphical approach; hydrogenerator governor tuning; integral gains; loading grid; pole cancellation method; proportional gains; rotor inertia; self-regulation constants; stability limits; turbine; water column time constants; Design methodology; Equations; Frequency; Pressure control; Proportional control; Stability; Three-term control; Torque control; Turbines; Velocity control;
Journal_Title :
Energy Conversion, IEEE Transactions on