• DocumentCode
    901702
  • Title

    Evaluation of the Radiation Hardness of the Ferranti F100-L Microprocessor in an Operating System

  • Author

    Baxter, N.E. ; Collings, I ; Hill, G.J. ; Roberts, B.C.

  • Author_Institution
    ERA Technology Ltd., Cleeve Road, Leatherhead, Surrey, KT22 7SA England
  • Volume
    29
  • Issue
    6
  • fYear
    1982
  • Firstpage
    1737
  • Lastpage
    1739
  • Abstract
    The performance of the Ferranti F100-L microprocessor and support chips was evaluated in neutron, high dose rate electron and total dose gamma irradiation, in which the safe operating levels were 2 × 1013 n/cm2, 2.2 × 107 rad/s (for data upset), and 1 - 10 Mrad (depending on dose rate) respectively. No latchup was obtained with 50ns infra-red laser pulses equivalent to 1013 rad/s.
  • Keywords
    Clocks; Electrons; Frequency; Isolation technology; Linear particle accelerator; Microprocessors; Neutrons; Operating systems; Test equipment; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1982.4336439
  • Filename
    4336439