DocumentCode
902940
Title
Post-Coupler and Stem Current Measurements for High Current CW Drift-Tube Linacs
Author
Ungrin, J. ; Schriber, S.O. ; Vokes, R.A.
Author_Institution
Atomic Energy of Canada Limited, Research Company Chalk River Nuclear Laboratories Chalk River, Ontario, Canada K0J 1J0
Volume
30
Issue
4
fYear
1983
Firstpage
3013
Lastpage
3015
Abstract
Post-coupler characteristics have been measured on a model Alvarez tank for drift-tube-to-outer tank diameter ratios from 0.10 to 0.25. A maximum ratio beyond which field stabilization is not possible and a minimum ratio where stabilization is difficult have been determined. Field stabilization has been studied using two to twenty-one post couplers in a 22 cell tank. A sensitive dependence of the drift-tube stem currents near the tank end walls on the end cell geometry has been found.
Keywords
Acceleration; Current measurement; Electromagnets; Frequency; Geometry; Impedance; Linear accelerators; Protons; Q factor; Size measurement;