• DocumentCode
    905496
  • Title

    The Vernier Delay Unit

  • Author

    Pierce, W.B.

  • Author_Institution
    Stanford Linear Accelerator Center Stanford University Stanford, California 94305
  • Volume
    32
  • Issue
    1
  • fYear
    1985
  • Firstpage
    95
  • Lastpage
    99
  • Abstract
    This module will accept differential ECL pulses from the auxiliary rear panel or NIM level pulses from the front panel. The pulses are produced at the output with a fixed delay that is software programmable in steps of 0.1 ns over the range of 0.1 to 10.5 ns. Multiple outputs are available at the front panel. Minimum delay through the module is 9 ns.
  • Keywords
    Backplanes; Calibration; Damping; Delay lines; Linear accelerators; Magnets; Pulse measurements; Space vector pulse width modulation; Testing; Timing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4336800
  • Filename
    4336800