• DocumentCode
    906324
  • Title

    An Experimental Study of Stable Operating Conditions for a High-Sensitivity Induction Gradiometer

  • Author

    Tashiro, Kunihisa ; Kakiuchi, Atsuya ; Moriizumi, Ken-Ich ; Wakiwaka, Hiroyuki

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Shinshu Univ., Nagano
  • Volume
    45
  • Issue
    6
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    2784
  • Lastpage
    2787
  • Abstract
    Stable operating conditions for a high-sensitivity induction gradiometer are studied experimentally. In order to reduce electrical interferences in our developed induction gradiometer, we construct a Faraday cage. It consists of copper mesh and wood, and is 2.0 mtimes1.8 mtimes1.8 m in size. Experimental results show that the inside of the cage can provide a quiet electrical environment where the electrical interference is suppressed. Choosing a suitable grounding point for the electronics, undesirable signals in the sensor output are cleaned. Observation of a weak magnetic field is also demonstrated.
  • Keywords
    interference; magnetometers; Faraday cage; electrical interferences; high-sensitivity induction gradiometer; weak magnetic field; Electrical interferences; Faraday cage; grounding; induction gradiometer;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2009.2020561
  • Filename
    4957753