Title :
Compensation Effects in Hadron Calorimeters
Author :
Gabriel, T.A. ; Bishop, B.L. ; Brau, J. ; Di Ciaccio, A. ; Goodman, M. ; Wilson, R.
Author_Institution :
Oak Ridge National Laboratory
Abstract :
The pros and cons of utilizing a fissionable material such as 238U to compensate for the nuclear binding energy losses in a hadron calorimeter are discussed. Fissionable material can return some lost energy to the particle cascade in terms of low-energy neutrons and gamma rays, but electromagnetic sampling inefficiencies (often called transition effects) and the detection medium which tries to convert this energy to a useable signal are just as important.
Keywords :
Argon; Electrons; Energy exchange; Energy loss; Fluctuations; Hydrogen; Iron; Mesons; Neutrons; Sampling methods;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :