DocumentCode :
907377
Title :
Computer Simulation of Semiconductor Dosimeters
Author :
Manfredotti, C. ; Nastasi, U. ; Zanini, A. ; Bonazzola, G.C.
Author_Institution :
Istituto di Fisica Superiore, UniversitÃ\xa0 di Torino and Istituto Nazionale di Fisica Nucleare, Sezione di Torino Corso M. D´´Azeglio 46, 10125 Torino (Italy)
Volume :
32
Issue :
1
fYear :
1985
Firstpage :
953
Lastpage :
956
Abstract :
A previous Monte Carlo program, ISIDE, for the simulation of semiconductor gamma ray detectors, has been extended to a new code, PHANTOM, which can be used either for calculating the gamma ray exposure from the output of semiconductor detectors working in pulse mode or for determining the isodose curves in a cylindrical phantom exposed to a disk gamma ray source. The results are used to evaluate the exposure from the spectra recorded by a HgI2 detector in the energy range 10 KeV - 1 MeV. A good agreement with experimental results either for phantoms and for semiconductor detectors is obtained.
Keywords :
Apertures; Circuit simulation; Collimators; Computational modeling; Computer simulation; Filters; Gamma ray detection; Gamma ray detectors; Imaging phantoms; Monte Carlo methods;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4336973
Filename :
4336973
Link To Document :