DocumentCode
908474
Title
Performance of the SLD Warm Iron Calorimeter Pre-Prototype
Author
Johnson, A.S. ; Busza, W. ; Friedman, J. ; Kendall, H. ; Kistiakowsky, V. ; Lyons, T. ; Osborne, L.S. ; Rosenson, L. ; Verdier, R. ; Garumbalis, D. ; Haber, C. ; Shaevitz, M. ; Shapiro, S.L. ; Johnson, J.R.
Author_Institution
Massachusetts Institute of Technology, Cambridge, MA 02139
Volume
33
Issue
1
fYear
1986
Firstpage
197
Lastpage
200
Abstract
The performance of a pre-prototype of the SLD Warm Iron Calorimeter (WIC) build with proportional tube cathode pad readout has been studied. The calorimeter was found to have an average resolution of 36.7 ± 0.2% for muons at 2.0, 5.0 and 10.5 GeV and 81 ± 2%/¿E for pion showers at 5.0 and 10.5 GeV. The mean energy found for the pion showers was consistent with a linear dependance on energy within these standard deviations.
Keywords
Aluminum; Argon; Cathodes; Copper; Detectors; Energy resolution; Iron; Lead; Mesons; Superluminescent diodes;