• DocumentCode
    908474
  • Title

    Performance of the SLD Warm Iron Calorimeter Pre-Prototype

  • Author

    Johnson, A.S. ; Busza, W. ; Friedman, J. ; Kendall, H. ; Kistiakowsky, V. ; Lyons, T. ; Osborne, L.S. ; Rosenson, L. ; Verdier, R. ; Garumbalis, D. ; Haber, C. ; Shaevitz, M. ; Shapiro, S.L. ; Johnson, J.R.

  • Author_Institution
    Massachusetts Institute of Technology, Cambridge, MA 02139
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    197
  • Lastpage
    200
  • Abstract
    The performance of a pre-prototype of the SLD Warm Iron Calorimeter (WIC) build with proportional tube cathode pad readout has been studied. The calorimeter was found to have an average resolution of 36.7 ± 0.2% for muons at 2.0, 5.0 and 10.5 GeV and 81 ± 2%/¿E for pion showers at 5.0 and 10.5 GeV. The mean energy found for the pion showers was consistent with a linear dependance on energy within these standard deviations.
  • Keywords
    Aluminum; Argon; Cathodes; Copper; Detectors; Energy resolution; Iron; Lead; Mesons; Superluminescent diodes;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337080
  • Filename
    4337080