DocumentCode
908770
Title
A Scintillator-Photodiode Position Detector
Author
Hall, G. ; Robinson, D. ; Seez, C. ; Siotis, I.
Author_Institution
The Blackett Laboratory, Imperial College, London SW7 2BL, U. K.
Volume
33
Issue
1
fYear
1986
Firstpage
310
Lastpage
313
Abstract
A detector providing two dimensional spatial measurement of calorimeter showers is described. It consists of scintillator fingers read out by photodiodes. Results from a prototype evaluated in a test beam are given, including the effects of charged particle detection by the photodiodes.
Keywords
Detectors; Energy measurement; Fingers; Particle beams; Performance evaluation; Photodiodes; Position measurement; Prototypes; Silicon; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1986.4337107