Obtaining transfer functions with zero steady-state error from impulse responses
Author
Allwright, J.C. ; Chuang, S.C.
Author_Institution
Imperial College, Control & Automation Section, Centre for Computing & Automation, London, UK
Volume
6
Issue
22
fYear
1970
Firstpage
706
Lastpage
708
Abstract
A technique is presented for obtaining approximations to the transfer function of a plant (by modelling the plant´s impulse response by a linear combination of orthonormal functions) so that the steady-state responses of the plant and its approximation are the same for constant input. An example is given.