DocumentCode
911343
Title
Fast Signal Calibration Systems for Large Detector System Front Ends
Author
Lo, C.C. ; Kirsten, F.A. ; Nakamura, M.
Author_Institution
Lawrence Berkeley Laboratory University of California Berkeley, California 94720 U.S.A.
Volume
34
Issue
1
fYear
1987
Firstpage
266
Lastpage
270
Abstract
The fast risetime of the calibration signal in a 10 ns front end of a large detector system presents problems not generally encountered in a slower system. The distribution of these signals also presents its own unique set of problems. We have arrived at solutions which are applicable to large systems requiring fast risetime calibration signals in a small volume of space.
Keywords
Cables; Calibration; Detectors; Hybrid integrated circuits; Hybrid power systems; Preamplifiers; Pulse generation; Superluminescent diodes; Timing; Wires;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1987.4337345
Filename
4337345
Link To Document