Abstract :
The letter presents noise calculations for Gunn amplifiers with both uniform and nonuniform field distributions. The results indicate that amplifiers with an injection-limited cathode contact, and hence a uniform field distribution, exhibit significantly lower noise figures than those having an ohmic cathode contact, which yields a nonuniform field distribution. A further reduction of noise could be obtained by using materials with high negative mobility.
Keywords :
Gunn devices; microwave amplifiers; noise; Gunn amplifiers; bulk negative resistance amplifiers; injection limited cathode contact; noise reduction;