DocumentCode
916645
Title
Frequency-stability improvement in a klystron stabilised by a superconducting cavity
Author
B¿¿nard, J. ; Jimenez, J.J. ; Sudraud, P. ; Viet, Nguyen Tuong
Author_Institution
Université Paris XI, Institut d´Ã\x89lectronique Fondamentale, Laboratoire associé au CNRS, Orsay, France
Volume
8
Issue
5
fYear
1972
Firstpage
117
Lastpage
118
Abstract
The measurements of the short-term and long-term stability of an X band klystron, stabilised by a high-Q-factor super-conducting cavity, show that this signal has a stability of 3 parts in 1012 for a period of measurement of 10 s and a frequency shift of 1.7 Hz during 30 min. These performances have been obtained by improving the operating parameters of the oscillator.
Keywords
cavity resonators; frequency stability; klystrons; superconducting devices; Q-factor; X band klystron; oscillator; stability; superconducting cavity;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19720084
Filename
4235531
Link To Document