• DocumentCode
    920348
  • Title

    Correlation-function display and peak detection

  • Author

    Jordan, J.R. ; Back, M.S.

  • Author_Institution
    University of Edinburgh, School of Engineering Science, Edinburgh, UK
  • Volume
    8
  • Issue
    24
  • fYear
    1972
  • Firstpage
    602
  • Lastpage
    604
  • Abstract
    A new method of correlation-function display and peak detection, based on the polarity correlator, is described. It is shown that the overload states of a parallel array of integrating counters, when displayed at regular intervals of elapsed integration time, define the correlation function. The system has been especially designed for use in correlation flowmeters.
  • Keywords
    correlation methods; display systems; flowmeters; correlation flowmeters; correlation function display; integrating counters; overload states; parallel array; peak detection; polarity correlator;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19720436
  • Filename
    4235902