Abstract
A good agreement between actual, Iarge-signal Gunn device operation and a first principles model has been achieved in terms of descriptive device parameters. An injection-locking technique was used to measure the variations of device conductance and capacitance with RF voltage amplitude. The equivalent circuits developed allow optimization of Gunn oscillator circuits.
Keywords
Capacitance; Equivalent circuits; Flanges; Gunn devices; Impedance measurement; Injection-locked oscillators; Microwave devices; Microwave oscillators; Radio frequency; Voltage;