DocumentCode :
934551
Title :
Beyond Parameter Estimation: Extending Biomechanical Modeling by the Explicit Exploration of Model Topology
Author :
Valero-Cuevas, Francisco J. ; Anand, Vikrant V. ; Saxena, Anupam ; Lipson, Hod
Author_Institution :
Southern California Univ., Los Angeles
Volume :
54
Issue :
11
fYear :
2007
Firstpage :
1951
Lastpage :
1964
Abstract :
Selecting a model topology that realistically predicts biomechanical function remains an unsolved problem. Today´s dominant modeling approach is to replicate experimental input/output data by performing parameter estimation on an assumed topology. In contrast, we propose that modeling some complex biomechanical systems requires the explicit and simultaneous exploration of model topology (i.e., the type, number, and organization of physics-based functional building blocks) and parameter values. In this paper, we use the example of modeling the notoriously complex tendon networks of the fingers to present three critical advances towards the goal of implementing this extended modeling paradigm. First, we describe a novel computational environment to perform quasi-static simulations of arbitrary topologies of elastic structures undergoing large deformations. Second, we use this form of simulation to show that the assumed topology for the tendon network of a finger plays an important role in the propagation of tension to the finger joints. Third, we demonstrate the use of a novel inference algorithm that simultaneously explores the topology and parameter values for hidden synthetic tendon networks. We conclude by discussing critical issues of observability, separability, and uniqueness of topological features inferred from input/output data, and outline the challenges that need to be overcome to apply this novel modeling paradigm to extract causal models in real anatomical systems.
Keywords :
biomechanics; biomechanical modeling; causal models; elastic structures; finger joints; model topology; parameter estimation; physics-based functional building blocks; quasistatic simulations; synthetic tendon networks; Computational modeling; Data mining; Deformable models; Fingers; Inference algorithms; Network topology; Observability; Parameter estimation; Predictive models; Tendons; Bioinformatics; biomechanical model; hand; machine learning; Algorithms; Biomechanics; Computer Simulation; Humans; Joints; Models, Biological; Movement; Muscle Contraction; Muscle, Skeletal;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2007.906494
Filename :
4352068
Link To Document :
بازگشت