Title :
New expression for mismatch uncertainty when measuring microwave attenuation
Author_Institution :
Royal Signals & Radar Establishment, Malvern, UK
fDate :
4/1/1980 12:00:00 AM
Abstract :
To find the mismatch uncertainty associated with a microwave-attenuation measurement, it is essential to determine the moduli of the source-and load-reflection coefficients at the insertion point and the moduli of the S parameters of the device under test. If the phase angles of the S parameters of the device under test are also measured, the mismatch uncertainty can be calculated from a new equation that is derived in this paper. By doing so, an example (based on the RSRE X-band-modulated subcarrier attenuator calibrator) shows that a large reduction in the total uncertainty is obtained at low values of attenuation, when calibrating a precision rotary-vane attenuator.
Keywords :
attenuation measurement; microwave measurement; S parameter phase angle; X-band subcarrier attenuator; microwave attenuation; mismatch uncertainty; reflection coefficients; rotary vane attenuator;
Journal_Title :
Microwaves, Optics and Antennas, IEE Proceedings H
DOI :
10.1049/ip-h-1.1980.0016