Title :
Active network for correcting impulse-voltage measurements
Author :
Liang, X. ; Martens, G.O.
Author_Institution :
University of Manitoba, Department of Electrical Engineering, Winnipeg, Canada
fDate :
9/1/1988 12:00:00 AM
Abstract :
High-voltage impulse measurements are usually carried out by using a divider system which may distort the impulse. The paper presents a method for the correction of the input signal from the distorted output signal by using a wide-band active network. The method is demonstrated by several test results. The accuracy analysis of the method is also carried out theoretically. The correction method is simple to apply.
Keywords :
active networks; broadband networks; high-voltage techniques; signal processing; voltage measurement; waveform analysis; HV impulse measurement; accuracy analysis; correction method; divider system; signal correction;
Journal_Title :
Physical Science, Measurement and Instrumentation, Management and Education - Reviews, IEE Proceedings A
DOI :
10.1049/ip-a-1.1988.0076