• DocumentCode
    948847
  • Title

    Active network for correcting impulse-voltage measurements

  • Author

    Liang, X. ; Martens, G.O.

  • Author_Institution
    University of Manitoba, Department of Electrical Engineering, Winnipeg, Canada
  • Volume
    135
  • Issue
    7
  • fYear
    1988
  • fDate
    9/1/1988 12:00:00 AM
  • Firstpage
    487
  • Lastpage
    492
  • Abstract
    High-voltage impulse measurements are usually carried out by using a divider system which may distort the impulse. The paper presents a method for the correction of the input signal from the distorted output signal by using a wide-band active network. The method is demonstrated by several test results. The accuracy analysis of the method is also carried out theoretically. The correction method is simple to apply.
  • Keywords
    active networks; broadband networks; high-voltage techniques; signal processing; voltage measurement; waveform analysis; HV impulse measurement; accuracy analysis; correction method; divider system; signal correction;
  • fLanguage
    English
  • Journal_Title
    Physical Science, Measurement and Instrumentation, Management and Education - Reviews, IEE Proceedings A
  • Publisher
    iet
  • ISSN
    0143-702X
  • Type

    jour

  • DOI
    10.1049/ip-a-1.1988.0076
  • Filename
    4648603