Variation with specimen size of some properties of Alcomax III at 50 Hz excitation
Author
Shepherd, William ; Gaskell, Harold ; Rashid, Parvez
Author_Institution
University of Bradford, Bradford, Yorks, England
Volume
10
Issue
1
fYear
1974
fDate
3/1/1974 12:00:00 AM
Firstpage
50
Lastpage
54
Abstract
When subjected to dynamic excitation at 50 Hz with sinusoidal field intensity, the power loss per unit volume, coercive force and remanent flux density of square-section specimens of Alcomax III were found to be functions of specimen size. At fixed excitation the coercive force increased and the remanent flux density decreased both as linear functions of specimen section side dimension. Loss per unit volume at low field intensities decreased as specimen size increased and was less than that calculated from the static
loops. With high field intensities the loss per unit volume increased with increase of specimen size and was in excess of that predicted by the static
loops.
loops. With high field intensities the loss per unit volume increased with increase of specimen size and was in excess of that predicted by the static
loops.Keywords
Alcomax III; Coercive force; Coils; Density measurement; Magnetic anisotropy; Magnetic cores; Magnetic field measurement; Magnetic flux; Perpendicular magnetic anisotropy; Saturation magnetization; Testing;