• DocumentCode
    955147
  • Title

    On using a sense wire to quantitate the magnetic flux leakage through an aperture in an electromagnetic shield

  • Author

    Taylor, C.D. ; Prather, W.D. ; Herrmann, Carl C.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Ohio Univ., Athens, OH
  • Volume
    31
  • Issue
    4
  • fYear
    1989
  • fDate
    11/1/1989 12:00:00 AM
  • Firstpage
    337
  • Lastpage
    341
  • Abstract
    A formulation is developed for determining the sensitivity of positioning a sense wire behind an aperture in an electromagnetic shield to quantitate the flux leakage through the aperture. Both hardened and unhardened circular apertures are considered. Comparisons with measured data are made to verify the analysis
  • Keywords
    magnetic leakage; magnetic shielding; circular apertures; electromagnetic shield; hardened aperture; magnetic flux leakage; sense wire; unhardened aperture; Apertures; Electromagnetic measurements; Electromagnetic shielding; Magnetic analysis; Magnetic flux leakage; Wire;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/15.43626
  • Filename