DocumentCode
955147
Title
On using a sense wire to quantitate the magnetic flux leakage through an aperture in an electromagnetic shield
Author
Taylor, C.D. ; Prather, W.D. ; Herrmann, Carl C.
Author_Institution
Dept. of Electr. & Comput. Eng., Ohio Univ., Athens, OH
Volume
31
Issue
4
fYear
1989
fDate
11/1/1989 12:00:00 AM
Firstpage
337
Lastpage
341
Abstract
A formulation is developed for determining the sensitivity of positioning a sense wire behind an aperture in an electromagnetic shield to quantitate the flux leakage through the aperture. Both hardened and unhardened circular apertures are considered. Comparisons with measured data are made to verify the analysis
Keywords
magnetic leakage; magnetic shielding; circular apertures; electromagnetic shield; hardened aperture; magnetic flux leakage; sense wire; unhardened aperture; Apertures; Electromagnetic measurements; Electromagnetic shielding; Magnetic analysis; Magnetic flux leakage; Wire;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/15.43626
Filename
43626
Link To Document