DocumentCode
956652
Title
Environmental and Life Testing of High Reliability Magnetic Components
Author
Colby, F.B. ; Ursch, R.R.
Author_Institution
Raytheon Co.
Volume
1
Issue
1
fYear
1965
fDate
6/1/1965 12:00:00 AM
Firstpage
109
Lastpage
114
Abstract
Over 2.5 million hours of life test have been accumulated in the process of manufacturing High Reliability Magnetic Components for Missile and Space Programs. These units were manufactured under a High Reliability Program and were subjected to qualification and acceptance tests as required by the customer´s specifications. The compiled life hours is composed of twenty-five electrical specifications and includes Power Transformers, Inductors, and Audio Transformers. Documentation of test records by serialization provides a complete history of each unit. This paper will discuss the results of the testing programs and the effects of environment upon the design of the component, also the effect of extended life test on the operation of the units.
Keywords
Burn-in tests; Environmental tests; High reliability; Inductors; Life tests; Transformers; Documentation; History; Inductors; Life testing; Manufacturing processes; Missiles; Performance evaluation; Power transformers; Qualifications; Temperature;
fLanguage
English
Journal_Title
Parts, Materials and Packaging, IEEE Transactions on
Publisher
ieee
ISSN
0018-9502
Type
jour
DOI
10.1109/TPMP.1965.1135359
Filename
1135359