DocumentCode
960362
Title
Peaking Transformer on a New Principle
Author
Boyajian, Aram
Author_Institution
Consulting Eng., Pittsfield, Mass
Volume
3
Issue
2
fYear
1956
fDate
9/1/1956 12:00:00 AM
Firstpage
66
Lastpage
68
Abstract
Highly peaked voltages are obtained by connecting a linear reactor in series with a steeply saturating reactor free from magnetic joints, if the combination is excited with a sinusoidal voltage, and the saturable reactor is tapped for the peaked voltage. Similar results may also be obtained from a composite design with plenty of magnetic joints if the return magnetic circuit is arranged in two parallel branches, one branch saturable and bearing the secondary winding, and the other nonsaturating, provided that the joints are so arranged as to make the equivalent parallel path for the secondary joint-free. Such a design is shown in Fig. 2 and explained in Fig. 3. A common wrong arrangement of the joints is shown and explained in Fig. 5. Peaked voltage obtained by the design of Fig. 6 is shown in Fig. 7.
Keywords
Circuit faults; Design engineering; Inductors; Magnetic circuits; Magnetic cores; Magnetic separation; Pulse shaping methods; Pulse transformers; Saturation magnetization; Voltage;
fLanguage
English
Journal_Title
Component Parts, IRE Transactions on
Publisher
ieee
ISSN
0096-2422
Type
jour
DOI
10.1109/TCP.1956.1135751
Filename
1135751