DocumentCode
972714
Title
The design of reinforcing steel systems for maglev guideways
Author
Burke, P.E.
Author_Institution
University of Toronto, Toronto, Canada
Volume
15
Issue
6
fYear
1979
fDate
11/1/1979 12:00:00 AM
Firstpage
1497
Lastpage
1499
Abstract
The use of standard reinforcing steel in concrete guideways for Maglev systems poses serious problems because of the high eddy current loss in the steel due to the large time varying magnetic fields of the cryogenic magnets. It is shown in this paper that these losses may be reduced to acceptable values by stranding the reinforcing steel and by making sure there are no closed loops in the reinforced system.
Keywords
Eddy current losses; Magnetic levitation, guideway transportation; Steel materials/devices; Conductors; Costs; Cryogenics; Drag; Eddy currents; Magnetic fields; Magnetic levitation; Steel; Superconducting magnets; Vehicles;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1979.1060415