DocumentCode
973487
Title
RF attenuation measurement system with 1-kHz voltage ratio standard
Author
Kawakami, Tomoteru ; Nagatuka, Akio ; Maeda, Masaaki ; Igarashi, Shigera
Author_Institution
Electrotech. Lab., Ibaraki, Japan
Volume
42
Issue
6
fYear
1993
fDate
12/1/1993 12:00:00 AM
Firstpage
1014
Lastpage
1019
Abstract
A homodyne system for measuring attenuation at 10 GHz and 30 MHz is constructed and evaluated. The radio frequency (RF) attenuation is converted to 1-kHz attenuation, and the 1-kHz attenuation is measured by an inductive voltage divider built in a 1-kHz receiver. A 1-kHz voltage ratio standard (VRS) is proposed to check the accuracy of the 1-kHz receiver for maintaining long-term accuracy. The differences between the VRS and the 1 kHz receiver are smaller than 0.0003 dB for 0-40 dB. A precision piston attenuator of 30 MHz agrees with the system within 0.0018 dB for 0-30 dB. The change in measured values at an interval of one year are less than 0.001 dB. The results demonstrate that this system can be expected to reliably maintain high accuracy
Keywords
attenuation measurement; detector circuits; measurement standards; microwave measurement; radio receivers; radiowave propagation; 0 to 30 dB; 1 kHz; 10 GHz to 30 MHz; RF attenuation measurement; homodyne system; inductive voltage divider; long-term accuracy; precision piston attenuator; voltage ratio standard; Attenuation measurement; Attenuators; Calibration; Circuits; Frequency conversion; Maintenance; Measurement standards; Pistons; Radio frequency; Voltage;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.245655
Filename
245655
Link To Document