• DocumentCode
    974488
  • Title

    A linear accelerator bunch length monitor

  • Author

    Jessie, Darryl ; Norum, Eric

  • Author_Institution
    Saskatchewan Accel. Lab., Saskatchewan Univ., Saskatoon, Sask., Canada
  • Volume
    43
  • Issue
    3
  • fYear
    1996
  • fDate
    6/1/1996 12:00:00 AM
  • Firstpage
    2154
  • Lastpage
    2162
  • Abstract
    A monitor has been developed that provides an indication of the bunching efficiency of the Saskatchewan Accelerator Laboratory´s linear accelerator (linac). By adjusting the prebuncher phase at the injector, a decrease in energy spread of 15% at the end of the linac was observed. With more rigorous optimization, it is believed that a reduction of 20% or greater in energy spread can be achieved
  • Keywords
    beam handling techniques; electron accelerators; electron beams; particle beam diagnostics; particle beam injection; Saskatchewan Accelerator Laboratory; bunching efficiency; electron beam; energy spread decrease; injector; linac; linear accelerator bunch length monitor; prebuncher phase; Acceleration; Electron accelerators; Electron beams; Energy measurement; Helium; Laboratories; Linear accelerators; Linear particle accelerator; Monitoring; Particle beams;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.502310
  • Filename