Abstract :
The multipole structure of Fermilab Energy Saver quadrupoles is obtained from low current, room temperature measurements using a rotational Morgan coil and lock-in amplifier. Multipole data are presented for the first forty Tevatron quadrupoles.
Keywords :
Accelerator magnets, superconducting; Harmonic analysis; Amplifiers; Current measurement; Energy measurement; Geometry; Harmonic analysis; Magnetic field measurement; Magnetic flux; Superconducting coils; Superconducting magnets; Temperature measurement;