DocumentCode :
982722
Title :
A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics
Author :
Passmann, Christian ; Ermert, Helmut
Author_Institution :
Dept. of RF Eng., Ruhr-Univ., Bochum, Germany
Volume :
43
Issue :
4
fYear :
1996
fDate :
7/1/1996 12:00:00 AM
Firstpage :
545
Lastpage :
552
Abstract :
A major design problem concerning high-frequency broad-band ultrasound imaging systems is caused by the strong dispersive attenuation of the tissue, which gives rise to images with inhomogeneous resolution and poor signal to noise ratio (SNR). To address the noise problem, strongly focused transducers with high energy density in a narrow focal region are utilized, which also provide more isotropic images due to improved lateral resolution. To account for the short depth of the focal area two suitable imaging conceptions are used: 1) synthetic aperture concept and 2) B/D-scan concept. To avoid the inhomogeneity of the images, different transmitter signals for each depth are applied, which are pseudoinversely prefiltered according to the transfer function of the tissue. To gain signal energy required for inverse filtering, a pulse compression technique with nonlinearly frequency modulated chirp signals is utilized. These procedures have been implemented in an ultrasound imaging system, which has been developed in the authors´ laboratory for eye and skin examinations, It can be used with transducers in a frequency range from 20 to 250 MHz.
Keywords :
biomedical ultrasonics; eye; skin; ultrasonic equipment; 100-MHz ultrasound imaging system; 20 to 250 MHz; B/D-scan concept; dermatologic diagnostics; images inhomogeneity; improved lateral resolution; inhomogeneous resolution; inverse filtering; noise problem; nonlinearly frequency modulated chirp signals; ophthalmologic diagnostics; poor signal to noise ratio; pulse compression technique; strong dispersive attenuation; strongly focused transducers; synthetic aperture concept; tissue attenuation; Dispersion; Energy resolution; Frequency; High-resolution imaging; Image resolution; Signal design; Signal resolution; Signal to noise ratio; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/58.503714
Filename :
503714
Link To Document :
بازگشت