DocumentCode :
984870
Title :
A critique of present calibration procedures for partial discharge measurements
Author :
Zaengl, Walter S. ; Lehmann, Kurt
Author_Institution :
Swiss Federal Inst. of Technol., Zurich, Switzerland
Volume :
28
Issue :
6
fYear :
1993
fDate :
12/1/1993 12:00:00 AM
Firstpage :
1043
Lastpage :
1049
Abstract :
The need for improved standardization procedures for use on different types of partial discharge (PD) measuring systems is discussed. This requirement is examined using recording and processing data of complex PD signals obtained from in-service electrical apparatus. It is concluded that more fundamental knowledge of the PD mechanisms must be gained before any significant changes in existing calibration procedures can be made
Keywords :
calibration; electric variables measurement; insulation testing; partial discharges; standardisation; PD measuring systems; calibration procedures; complex PD signals; in-service electrical apparatus; partial discharge measurements; standardization procedures; Calibration; Circuit testing; Current measurement; Partial discharge measurement; Partial discharges; Pollution measurement; Power generation; Pulse circuits; Pulse measurements; Signal generators;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/14.249377
Filename :
249377
Link To Document :
بازگشت