• DocumentCode
    986397
  • Title

    Attenuation measurements of leaky waves by the acoustic line-focus beam

  • Author

    Kushibiki, J. ; Matsumoto, Yuki ; Chubachi, N.

  • Author_Institution
    Tohoku University, Department of Electrical Engineering, Faculty of Engineering, Sendai, Japan
  • Volume
    19
  • Issue
    14
  • fYear
    1983
  • Firstpage
    512
  • Lastpage
    514
  • Abstract
    A new method of direct attenuation measurement of leaky waves is proposed through V(z) curves obtained by the line-focus-beam acoustic microscope, simultaneously giving the corresponding wave velocity. Experiments are demonstrated for fused quartz with an acoustic line-focus-beam sapphire lens of 1.0 mm radius at 226.3 MHz. The attenuation measurement is achieved with a sufficient accuracy of about 5% as compared with the calculated value.
  • Keywords
    acoustic microscopes; acoustic wave absorption; attenuation measurement; surface acoustic waves; SAW; acoustic line-focus beam; acoustic microscope; attenuation measurement; fused quartz; leaky waves; sapphire lens; surface acoustic waves; wave velocity;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19830348
  • Filename
    4247838