• DocumentCode
    986982
  • Title

    Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of PPG Signal in Children by HRV Analysis

  • Author

    Gil, Eduardo ; Mendez, Martín ; Vergara, José María ; Cerutti, Sergio ; Bianchi, Anna Maria ; Laguna, Pablo

  • Author_Institution
    Aragon Inst. of Eng. Res., Univ. of Zaragoza, Zaragoza
  • Volume
    56
  • Issue
    4
  • fYear
    2009
  • fDate
    4/1/2009 12:00:00 AM
  • Firstpage
    1005
  • Lastpage
    1014
  • Abstract
    In this paper, an analysis of heart rate variability (HRV) during decreases in the amplitude fluctuations of photopletysmography (PPG) [decreases in the amplitude fluctuations of photopletysmography (DAP)] events for obstructive sleep apnea syndrome (OSAS) screening is presented. Two hundred and sixty-eight selected signal segments around the DAP event were extracted and classified in five groups depending on SaO2 and respiratory behavior. Four windows around each DAP are defined and temporal evolution of time-frequency HRV parameters was analyzed for OSAS screening. Results show a significant increase in sympathetic activity during DAP events, which is higher in cases associated with apnea. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the HRV indexes. The ratio of DAP events per hour r DAP and the ratio of apneic DAP events per hour r alpha DAP were computed. Results show an accuracy of 79% for r alpha DAP (12% increase with respect to r DAP), a sensitivity of 87.5%, and a specificity of 71.4% when classifying 1-h polysomnographic excerpts. As for clinical subject classification, an accuracy of 80% (improvement of 6.7% ), a sensitivity of 87.5%, and a specificity of 71.4% are reached. These results suggest that the combination of DAP and HRV could be an improved alternative for sleep apnea screening from PPG with the added benefit of its low cost and simplicity.
  • Keywords
    medical signal processing; pneumodynamics; sleep; HRV analysis; amplitude fluctuations; apneic events; heart rate variability; linear discriminant analysis; nonapneic events; obstructive sleep apnea syndrome; photopletysmography signal; polysomnographic excerpts; respiratory behavior; signal classification; signal extraction; sixty-eight selected signal segments; sympathetic activity; temporal evolution; time 1 h; Biomedical engineering; Communications technology; Digital audio players; Fluctuations; Gas insulated transmission lines; Heart rate variability; Linear discriminant analysis; Pediatrics; Signal analysis; Sleep apnea; Time frequency analysis; Children; decreases in the amplitude fluctuations of photopletysmography (PPG); heart rate variability (HRV); pulse PPG; sleep apnea; time–frequency; Child, Preschool; Electrocardiography; Heart Rate; Humans; Models, Cardiovascular; Photoplethysmography; Polysomnography; Pulse; ROC Curve; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Sleep Apnea Syndromes;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.2009340
  • Filename
    4671121