DocumentCode :
988654
Title :
Improvements in Insulation for High-Voltage A-C. Generators
Author :
Hill, C.F.
Author_Institution :
Research Laboratory, Westinghouse Elec. & Mfg. Co., East Pittsburgh, Pa.
Volume :
47
Issue :
3
fYear :
1928
fDate :
7/1/1928 12:00:00 AM
Firstpage :
845
Lastpage :
852
Abstract :
A discussion is given of the insulation problem in relation to increased size, rating, and voltages of turbo alternators and some results of experimental studies given showing the possibilities of improving the insulation to take care of such increases. Mention is made of the effects of high voltage testing and the use of hydrogen on the insulation problem and finally an explanation of a device for the elimination of corona formed around armature coils.
Keywords :
Alternators; Coils; Conductors; Corona; Dielectrics and electrical insulation; Gases; Hydrogen; Temperature; Turbines; Voltage;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1928.5055066
Filename :
5055066
Link To Document :
بازگشت