• DocumentCode
    999689
  • Title

    A ROM-based high-accuracy line frequency and line frequency deviation meter

  • Author

    Banta, Larry E. ; Xia, Yongping

  • Author_Institution
    Dept. of Mech. & Aerosp. Eng., West Virginia Univ., Morgantown, WV, USA
  • Volume
    39
  • Issue
    3
  • fYear
    1990
  • fDate
    6/1/1990 12:00:00 AM
  • Firstpage
    535
  • Lastpage
    539
  • Abstract
    The meter is based entirely on basic digital circuits and does not include a microprocessor. A large-capacity ROM is used to convert the data, which are proportional to the line period, into line frequency and line frequency deviation. The meter provides 0.001-Hz resolution and an updating speed of 4 times per second. A computer algorithm for developing the ROM memory map is also presented. A prototype of the meter has been constructed and found to work well
  • Keywords
    computerised instrumentation; digital instrumentation; frequency measurement; frequency meters; power system measurement; read-only storage; ROM; ROM memory map; computer algorithm; digital circuits; frequency meter; line frequency deviation meter; power lines; prototype; Clocks; Costs; Counting circuits; Frequency conversion; Frequency measurement; Microprocessors; Read only memory; Semiconductor device measurement; Switches; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.106288
  • Filename
    106288