شماره ركورد :
624677
عنوان مقاله :
Effect of Denture Cleansers on Tensile Bond Strength of Soft Liners to Denture Base Resin
عنوان فرعي :
بررسي اثر محلولهاي تميزكننده بر مقاومت باند كششي لايه هاي نرم به بيس پروتز
پديد آورندگان :
Geramipanah، Farideh نويسنده Member of Dental Implant Research Center and Associate Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sci , , Moradi Haghighi ، Ali akbar نويسنده Dentist , , Zeighami ، Somayeh نويسنده Member of Dental Research Center and Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Science. Te ,
اطلاعات موجودي :
فصلنامه سال 1392 شماره 87
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
8
از صفحه :
134
تا صفحه :
141
كليدواژه :
acrylic resins , Cleansing solutions , denture liners , tensile strength
چكيده لاتين :
Abstract Background and Aim: Optimal bond strength between soft liners and denture base resin is an important requirement for application of these materials. This study aimed to deter-mine the effect of 2.5% sodium hypochlorite (NaOCl) and Corega denture cleanser solu-tions on tensile bond strength of Acropars, Molloplast-B, GC soft liner and Mollosil soft liners to denture base resin. Materials and Methods: In this in-vitro experimental study, 30 specimens of each of the 4 soft liners according to the manufacturer’s instructions were processed between two blocks of polymethyl methacrylate. Specimens were divided into 3 groups and after im-mersion in 2.5% sodium hypochlorite and Corega solutions were subjected to tensile bond strength testing using Universal Testing Machine (Zwick Roell, Z50, Germany) with a crosshead speed of 5 mm/min. Data were analyzed with two-way ANOVA, Tamhane’s post hoc test and Fisher’s exact test. Results: The mean tensile bond strength of all three testing positions was 3.27? 1.04, 0.93?0.35, 0.71?0.31 and 0.28 ?0.11 MPa for Acropars, Molloplast-B, GC soft liner and Mollosil, respectively. Type of soft liner material had a significant effect on the tensile bond strength of soft liner to denture base resin (P < 0.0001) but type of cleansing solution had no significant influence on tensile bond strength of specimens. Conclusion: The 2.5% sodium hypochlorite and Corega solutions had no significant effect on tensile bond strength of soft liners to denture base. Key Words: Cleansing solutions , tensile strength , acrylic resins , denture liners
سال انتشار :
1392
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 87 سال 1392
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت