عنوان مقاله :
مروري بر حفاظت در برابر پرتو در راديولوژي تشخيصي
عنوان فرعي :
Review on radiation protection in diagnostic radiology
پديد آورندگان :
كرمی، وحید نويسنده Department of Medical Physics, Student Research Committee, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Karami, Vahid , ذبیحزاده، منصور نويسنده Department of Medical Physics, Student Research Committee, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Zabihzadeh, Mansour
اطلاعات موجودي :
ماهنامه سال 1395 شماره 0
كليدواژه :
راديولوژي تشخيصي , Radiography , ارگانهاي در خطر , حفاظت تشعشعي , Radiation Protection , Organs at risk
چكيده فارسي :
كشف پرتو ایكس و استفاده از آن برای تصویربرداری پزشكی دستاوردهای بزرگی برای تشخیص و درمان بیماریها فراهم كرد. روزانه بیش از 10 میلیون آزمون رادیولوژی تشخیصی و بیش از 100000 آزمون پزشكی هستهای در دنیا انجام میشود. بر اساس گزارش 160 كمیسیون ملی حفاظت رادیولوژیكی و اندازهگیریها، پرتو ایكس پزشكی در حدود 95% تمام آزمونهای رادیولوژیكی را شامل میشود كه سهمی 74% در دوز تجمعی جمعیت ایالات متحده آمریكا دارد. با وجود منافع منحصربهفرد پرتوهای یونیزان، از دیدگاه حفاظت در برابر پرتو منشای خطرات بالقوهای مانند سرطان و ناهنجاریهای ژنتیكی هستند. ریسك سرطان ناشی از رادیولوژی تشخیصی در حدود 6/%0 تا 3% برآورد میشود. تخمین زده میشود كه دوز ناشی از آزمونهای رادیولوژی تشخیصی سالانه مسئول 7587 و 5695 مورد سرطان بهترتیب در جمعیت ژاپن و ایالات متحده آمریكا است. اگرچه دوز بیشتر آزمونهای رادیولوژیكی تشخیصی بسیار پایین است اما افزایش سریع استفاده از آزمونهای پرتونگاری در دو دهه گذشته موجی از نگرانیها را درباره اثرات سرطانزای پرتوهای یونیزان ایجاد كرده است. بر اساس مدل خطی بدون آستانه برای منحنی دوز پاسخ هر میزانی از پرتوگیری خطرناك است. بر اساس توصیههای مراجع تنظیمكننده قوانین حفاظت تشعشعی، آزمون رادیولوژیكی باید به گونهای انجام شود كه پرتوگیری بیمار و جامعه بهصورت معقول و دستیافتنی تا حد ممكن پایین باشد. بهینهسازی عوامل متعددی مانند محدودسازی میدان تابش اولیه به ناحیه تابشی مورد نظر، شرایط تابش، تكنیكها، زمان پرتودهی و حفاظ، ضمن حفظ كیفیت تصویر میتواند پرتوگیری بیمار را كاهش میدهد. رعایت دستوركارهای حفاظتی میتواند مخاطرات پرتوگیری را بهطور قابل ملاحظهای كاهش دهد.
چكيده لاتين :
Discovery of x-ray and using of it for medical imaging have produced tremendous outcomes for diagnosis and treatment of diseases. More than 10 million diagnostic radiological procedures and 100,000 nuclear medicine exams are being performed daily around the world. According to the national commission on radiological protection and measurements (NCRP)-report 160, medical x-ray is contribute to approximately 95% of all radiological examinations that is responsible for 74% of the collective dose to the US population. Despite of unique benefits of ionizing radiations, in the field of radiation protection, they are associated with potential risks such as cancer and genetically abnormalities. The cancer risk attributable to diagnostic radiology is estimated about 0.6% to 3%. It is estimated that the radiation dose from diagnostic x-ray procedures are annually responsible for 7,587 and 5,695 cases of radiation induced cancer in the population of Japan and US, respectively. Although the radiation dose associated with most radiological procedures are very low, but rapid increasing use of radiography procedures during two past decades have been concerned due to the cancer risk associated with ionizing radiations. On the base of linear no-threshold (LNT) model of dose-response curve, any level of exposure is dangerous. Deoxyribonucleic acid (DNA) is the main target of ionizing radiation. For radiological exposure with low dose, the stochastic effects such as genetic damages and leukemia are concerned. According to the recommendations of the radiation protection regulatory organizations, radiological procedure must be done with respect to social and economic factors in which exposure of patient and population kept as low as reasonable and achievable. Hence, prescription of a radiological test is acceptable only when its advantages are higher than its damages. Optimizing the different parameters such as: collimating the primary beam field to the area of diagnostic interest, exposure conditions (high kVp and low mAs), projections, exposure time and shielding can reduce the patientsʹ exposure besides the saving of image quality. Following the radiation protection guidelines can considerably decrease the exposure risks.
عنوان نشريه :
مجله دانشكده پزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
مجله دانشكده پزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
ماهنامه با شماره پیاپی 0 سال 1395
كلمات كليدي :
#تست#آزمون###امتحان